Account
- Marketplace
- Cart
- Orders
- Quotes
- Wishlist
- Comparison list
When electrical systems fail due to improper wire selection, the consequences extend beyond inconvenience—they threaten project timelines, budgets, and professional reputations. Building wire represents the circulatory system of modern construction, and understanding its specifications separates successful installations from costly callbacks.
Building wire refers to insulated electrical conductors designed for permanent installation within commercial, industrial, and residential structures. The most common designations—THHN, THWN, and XHHW—indicate specific insulation properties that determine where and how the wire can be safely installed. Selecting the wrong type doesn't just risk inspection failures; it creates genuine fire hazards and liability exposure.
The conductor material debate generates strong opinions, yet the optimal choice depends entirely on application context.
| Property | Copper | Aluminum | Copperweld |
|---|---|---|---|
| Conductivity | Excellent (baseline) | Good (requires larger gauge) | Good (copper cladding) |
| Cost per foot | Baseline | 60-70% less | 15-25% more |
| Flexibility | High | Moderate | Low (steel core) |
| Termination | Standard connectors | Requires anti-oxidant compound | Standard copper methods |
| Best applications | Residential, branch circuits | Large feeders, service entrance | Grounding, overhead spans |
| Gauge comparison | 12 AWG = 20A | 10 AWG = 20A | Application-specific |
The material decision should never rest on upfront cost alone. Calculate total installed cost including labor, connectors, and larger conduit for aluminum. In runs under 100 feet for circuits below 60 amps, copper consistently delivers better economics when you factor installation time and long-term reliability.
Sergey Fedorov, Co-founder & CTO
The American Wire Gauge (AWG) system runs counterintuitively—smaller numbers indicate larger conductors. Three critical factors determine appropriate gauge selection:
Load Calculation
NEC requires conductors sized for 125% of continuous loads. A 16-amp continuous load necessitates wire rated for at least 20 amps—typically 12 AWG copper.
Voltage Drop
Should remain below 3% for branch circuits. A 14 AWG circuit adequate for 15 amps over 50 feet may suffer unacceptable voltage drop at 100 feet, requiring upsizing to 12 AWG.
Derating Factors
Ambient temperature and conduit fill can reduce capacity by 50% or more in hot environments or crowded raceways.
| Circuit Length | 15A Load | 20A Load | 30A Load | Voltage Drop |
|---|---|---|---|---|
| 50 feet | 14 AWG | 12 AWG | 10 AWG | 3.6V (3%) |
| 100 feet | 12 AWG | 10 AWG | 8 AWG | 3.6V (3%) |
| 150 feet | 10 AWG | 8 AWG | 6 AWG | 3.6V (3%) |
| 200 feet | 8 AWG | 6 AWG | 4 AWG | 3.6V (3%) |
The alphabet soup of designations encodes critical performance characteristics that determine where wire can be safely installed.
| Wire Type | Dry Rating | Wet Rating | Primary Applications | Cost Premium |
|---|---|---|---|---|
| THHN | 90°C | Not rated | Interior branch circuits, dry conduit | Baseline |
| THWN | 90°C | 75°C | Wet locations, outdoor conduit | 5-8% |
| THHN/THWN-2 | 90°C | 90°C | Universal applications | 8-12% |
| XHHW-2 | 90°C | 90°C | Underground, constant moisture | 20-25% |
THHN represents the workhorse of modern installations—rated for 90°C in dry locations with excellent abrasion resistance. THHN/THWN-2 combines both certifications, offering maximum versatility. XHHW-2 employs cross-linked polyethylene that excels in challenging environments with persistent moisture exposure.
Metal building installations present unique grounding and routing challenges. The conductive steel framework creates multiple grounding paths but introduces potential electromagnetic interference. NEC Article 250 requires bonding all metallic building components to the electrical grounding system—the metal skin cannot serve as the equipment grounding conductor.
Routing typically employs EMT, rigid metal conduit, or MC cable. Drilling through structural steel demands proper hole sizing and protective grommets. The metal building's thermal expansion characteristics necessitate expansion fittings on long conduit runs.
Metal buildings amplify two common mistakes: inadequate grounding and poor thermal management. The steel structure becomes a massive heatsink that changes ampacity calculations. Always verify ambient temperature at the conductor location—I've documented roof-mounted conduit exceeding 140°F ambient, requiring aggressive derating that surprised contractors using standard 86°F calculations.
Sergey Fedorov, Co-founder & CTO
| Method | Materials | Cost | Flexibility | Best Applications |
|---|---|---|---|---|
| Individual conductors in conduit | THHN EMT/PVC/RMC | High initial | Maximum (easy modifications) | Commercial, industrial |
| MC Cable | Metal-clad assembly | Medium | Good | Commercial, exposed runs |
| NM-B (Romex) | Non-metallic cable | Low | Limited (concealed only) | Residential |
| Direct burial (USE-2) | Underground rated | Medium | Poor (permanent) | Outdoor circuits |
Individual THHN conductors in conduit represent the gold standard for commercial installations, offering maximum flexibility for circuit modifications. MC cable accelerates installation while maintaining protection. NM-B dominates residential work but code strictly limits applications to concealed runs within cavities.
⚡ Voltage Rating
Typically 600V for building wire, providing safety margin above utilization voltage. Never substitute low-voltage wire rated for 300V or less.
🌡️ Temperature Ratings
Impact allowable ampacity, but termination equipment typically limits installations to 75°C regardless of conductor insulation per NEC Section 110.14(C).
🔧 Conductor Stranding
Solid conductors (10 AWG and smaller) resist deformation during termination but complicate pulling. Stranded conductors ease installation in complex runs, cost 15-25% more.
☀️ UV Resistance
Standard THHN lacks UV resistance and degrades under direct sunlight. Specify THHN-UV for outdoor applications.
Article 310 governs conductor applications. Section 310.15(B)(16) provides baseline ampacity, but multiple adjustment factors modify these values:
More than three current-carrying conductors trigger reductions: four to six conductors = 80% capacity, 21-30 conductors = 50% capacity.
At 40°C ambient (104°F), a 90°C conductor operates at 91% capacity. At 50°C, capacity drops to 82%. These factors stack multiplicatively with conduit fill derating.
Ready to Choose the Right Building Wire?
Get professional guidance on selecting the perfect building wire for your electrical installation. Our experts will help you calculate the correct gauge, choose between copper and aluminum, and ensure NEC compliance for residential and commercial projects.
Shop Building WiresStay tuned
Free and usefull digest on solar energy. No spam